The SBI12-BLD is Used in Conjunction with a REDARC Manager15 or Manager30 BMS to Protect the Auxiliary Battery from Excessive Discharge
Specifically designed for use as the load disconnect solenoid controlled by the BMS, the black (earth wire) should be connected to the load pin of the BMS.
The BMS sets the turn on and turn off points through its settings and switches this black wire (earth when loads should be on, no earth when loads should be off), and there is additional voltage thresholds monitored by the Smart Start SBI12-BLD to ensure reliable solenoid engagement.
Voltage Spike Protection
The SBI12-BLD smart start battery isolator incorporates a number of spike protection components specifically designed to reduce the risk of damaging the unit, and is designed to prevent any spikes generated by the solenoid coil from affecting vehicle equipment.
Features:
- Overmould design
- Compact in size and easy to install
- Silver contacts for longer life and suitable for marine applications
- Power saving technology
- Fault indication
- Fully surge protected
Specifications:
- System Voltage: 12V Nominal
- Turn ON Voltage: 10.2V
- Turn OFF Voltage: 10.0V
- Turn ON Delay: 5 sec
- Turn OFF Delay: 10 sec
- Max. Cont. Current: 100 Amps
- Max. Inrush Current: 400Amps
- Standby Current: < 5mA
- Operating Current: <0.1A
- Dimensions: 75 x 70 x 80mm
- Weight (g): 200
- Standards: CE, C-Tick, AS/NZS CISPR11:2004
- Main Stud Torque: 5-6.2 Nm
(SBI12BLD)